Vortex flowmeter in the condition of no medium activity, there are field appearances or signal output main reasons: poor grounding, causing electromagnetic interference; High frequency interference of strong electric equipment; The vibration of the pipeline is too large; The flexibility of the converter is too high: after the vortex flowmeter is powered on, there is media flowing through, but there is no field display or signal output. The main reason is that the flowmeter hardware is faulty, such as the power line is blocked, and the amplifier plate is damaged.

The pipeline is blocked; The practical flow value is too small, and the operation is below the lower limit of the flowmeter: the output signal of the vortex flowmeter is unstable, and the beating is very large. There is strong electric interference; There is pulsating flow or two-phase flow in the medium in the pipeline. Vibration of pipeline; The gasket is protruded into the tube; The valves of the front and rear devices of the flowmeter have interference; The medium does not fill the pipeline; There is cavitation in the pipeline.

The occurrence of the flowmeter body has debris winding: the measurement error of the vortex flowmeter is larger than that of the main reason: instrument hardware problems; The length of the straight pipe section at the front and back is lacking; The fluctuation of supply voltage is relatively large; The flowmeter device is different from the pipe, or the gasket is convex into the pipe; The inner diameter difference between instrument and pipe is too large; Two-phase flow or pulsating flow in the presence of a medium.

Pipeline leakage: vortex flowmeter measurement pipe leakage main reasons: the pressure in the pipeline is too high; The nominal pressure is not selected correctly; The seal is damaged; The sensor has been corroded: the vortex flowmeter sensor makes an abnormal roar mainly because the medium velocity is too fast, causing the flowmeter to tremble violently; There is cavitation phenomenon in the medium in the pipeline; There is a possibility of loosening the flow meter.

Send Inquiry