FLOWT / THREADED LIQUID FLOW MEASUREMENT
Small-Bore Pulse Liquid Turbine Flow Meter
A compact in-line sensor for clean, compatible liquids-selected around your flow range, threaded connection and receiving electronics.

Specify the sensor around the job
This LWGY-series configuration uses a turbine rotor in the liquid stream and a pickup connection for pulse-based measurement. The slim threaded body is intended for installation within a liquid line, rather than mounting on the outside of a pipe.
For equipment builders and plant buyers, selection starts with the actual liquid and operating flow. Match the meter range, wetted materials and electrical interface before finalising the installation.
LWGY
Turbine measurement series
304 SS
Listed body material
PULSE
Signal for matched electronics
01 / PRODUCT GUIDE
Check the Application Fit First
Clean, single-phase liquids that are compatible with the complete wetted assembly, with normal and minimum flow inside the selected meter's calibrated range.
Typical enquiries include water-based equipment, liquid transfer monitoring and pulse counting within OEM systems. An in-line installation needs access for mechanical fitting and future inspection.
Ask for review when conditions change
Viscosity: Thicker liquids or viscosity changes with temperature can change the calibration relationship.
Particles and fibres: Debris can obstruct or damage a moving rotor; discuss filtration and liquid cleanliness.
Air and pulsation: Entrained gas and strongly pulsating flow can affect the measurement.
Very low flow: A small connection does not by itself establish the minimum measurable flow.
Confirm My Liquid & Flow Range →
02 / PRODUCT GUIDE
How Liquid Flow Becomes a Pulse Signal
Liquid turns the rotor
The liquid passes through the in-line body and drives the internal turbine rotor. Stable, full-liquid flow conditions help the sensor operate consistently.
The pickup senses rotation
The pickup detects rotor movement and produces a signal for suitable receiving electronics. Confirm whether the ordered version supplies a raw pickup signal or a conditioned pulse.
Calibration links pulses to volume
The receiving instrument applies the meter-specific K-factor or calibration curve to interpret pulse frequency and pulse count.
Your system uses the result
A compatible counter, indicator or PLC can use the signal for flow indication or volume counting. Batch control requires the appropriate external control equipment and configuration.
03 / PRODUCT GUIDE
Separate the Product Data from the Options
The table distinguishes the shown threaded sensor from performance grades and electronics that depend on the selected LWGY configuration. Request the final size-specific specification with the quotation.
| Item | Product information |
|---|---|
| Measurement / series | In-line liquid turbine measurement / LWGY series |
| Body / connection | 304 stainless steel listed; small-bore threaded construction as shown |
| Signal | Pulse-based pickup; electrical form, signal level, wiring and any required supply depend on the selected version |
| Series accuracy grades | ±1%R or ±0.5%R (R = reading); a ±0.2%R high-precision grade is referenced for the series and requires specific confirmation |
| Series repeatability | Short-term repeatability of 0.05%–0.2% is referenced in the series data; confirm applicable conditions for the ordered meter |
| Liquid viscosity guidance | The series description refers to kinematic viscosity below 5 × 10−6 m2/s (5 cSt) at operating temperature. Higher-viscosity use needs application and calibration review. |
| Display and communications | Display, current output and communication functions require a matched electronics configuration; they are not implied by the pictured cable pickup |
Size-specific confirmation: agree the bore, minimum/normal/maximum flow, pressure, temperature, thread standard, seal materials and output details. These limits should come from the configuration offered for your application.
04 / PRODUCT GUIDE
Turn Pulses into Useful Flow and Volume Data
A K-factor expresses the number of pulses associated with a unit of liquid volume. Use the calibration information for the actual meter, and keep the units consistent throughout the receiving system.
Flow rate
Q = 60 × f / K
Q in L/min; f in Hz; K in pulses/L.
Total volume
V = N / K
V in litres; N is the accumulated pulse count; K in pulses/L.
Illustrative calculation: if K = 1000 pulses/L, a 50 Hz signal represents 3 L/min. Counting 2500 pulses represents 2.5 L. These assumed numbers explain the calculation; they are not this product's calibration values.
Use a single K-factor only over the range and conditions for which it is valid. Where the supplied calibration requires a correction curve or multiple factors, configure the receiving electronics accordingly.
05 / PRODUCT GUIDE
Check the Pulse Interface Before Connecting a PLC
| Confirm with FlowT | Why the receiving system needs it |
|---|---|
| Output electrical form | A pickup signal, voltage pulse and transistor output are not interchangeable. Specify the receiving input type before wiring. |
| Power and signal levels | Agree supply requirements, allowed voltage levels, polarity and wiring. Do not infer a supply rating from another LWGY electronics version. |
| Counter speed and scaling | Check the maximum expected pulse frequency against the receiving input capability; match the calibration units and count interpretation. |
| Cable and installation | Confirm cable routing, shielding, termination and any required signal conditioner for the site. |
If your project needs 4–20 mA, RS485, a local display or a totaliser, request a compatible configuration separately. A pulse sensor alone does not establish those functions.
Check Pulse Output Compatibility →
06 / PRODUCT GUIDE
Consider the Equipment and the Liquid Together
| Application direction | What to establish before selection |
|---|---|
| OEM water equipment | For suitable clean-water lines, identify actual flow demand, minimum operating flow and the counter or controller that will receive the signal. |
| Liquid transfer monitoring | For repeat transfer tasks, review temperature and viscosity consistency, entrained air and the required volume-counting arrangement. |
| Skid and machine utilities | Check available installation length, service access, thread requirements and pipe support rather than connection size alone. |
| Compatible process liquids | Provide composition and concentration. Body material alone does not confirm compatibility of the rotor, bearings and seals. |
Explore the FlowT turbine flow meter range for other configurations, or discuss a flow measurement solution for your equipment. Food-contact, drinking-water and hazardous-area requirements need their own documented configuration review.
07 / PRODUCT GUIDE
Confirm the Thread and the Wetted Assembly
A compact threaded body still needs a complete mechanical specification. State the required connection size and thread standard, and ask for the matching dimensional drawing.
Mechanical fit: confirm thread form, sealing method, overall length, installation orientation and access for assembly. Similar-looking threads should not be treated as interchangeable.
Liquid compatibility: review all wetted components and seals against the liquid composition, concentration and operating temperature. The listed 304 body does not define every internal component.
Operating limits: agree pressure and temperature ratings for the exact body, seals and electronics offered.

08 / PRODUCT GUIDE
Prepare the Line for Installation
Clean the line before fitting
Remove construction debris before installing the meter. Discuss upstream filtration for the actual liquid and the selected rotor assembly; use the specified filter arrangement.
Follow flow direction and installation guidance
Observe the meter's direction marking and keep the measurement chamber full of liquid. Confirm orientation, straight-pipe requirements and the location relative to pumps and valves.
Support the pipe and protect the connections
Avoid transferring pipe loads or misalignment into the small threaded body. Fit and seal the connection according to the supplied mechanical instructions.
Commission under controlled conditions
Introduce liquid according to the operating instructions, avoiding abrupt surges and rotor overspeed. Check for leaks and verify a stable signal before relying on the result.
This is an in-line instrument. Plan isolation, depressurisation and maintenance access for installation or removal. Confirm detailed installation dimensions and requirements for the ordered model.
09 / PRODUCT GUIDE
Use the First Reading to Establish a Baseline
| What you observe | Checks that help narrow the cause |
|---|---|
| No pulses or no indicated flow | Check the process flow, the selected measurement range, wiring and receiving input. Verify the actual signal type and any supply or conditioning requirement. |
| Unstable indication | Review air bubbles, flow pulsation, changing liquid conditions, electrical interference and the installation arrangement. |
| Unexpected accumulated volume | Check K-factor units, pulse scaling, counting method and missed or false pulses. Compare against a suitable reference under the same conditions. |
| A change after service | Review filter condition, rotor freedom, liquid cleanliness and any configuration changes, following the manufacturer's service instructions. |
Keep the meter identification, calibration data, liquid temperature, operating flow and receiving settings in the handover record. Set inspection and verification intervals around service conditions; a moving-rotor meter should not be assumed maintenance-free.
10 / PRODUCT GUIDE
Build a Clear Configuration and Quotation
Send one set of application data so mechanical, electrical and procurement requirements can be checked together. The quotation should identify the agreed configuration and the scope of supply.
| Selection item | Include in your enquiry |
|---|---|
| Liquid | Name, composition, concentration, cleanliness and viscosity at operating temperature |
| Flow conditions | Minimum, normal and maximum flow, units, temperature, pressure and any pulsation |
| Mechanical connection | Required thread standard and size, available length, pipe layout and installation orientation |
| Signal and control | Receiving device/input specification, required indication or totalisation, and any additional output requirement |
| Materials and records | Wetted-material and seal requirements, calibration information and any required compliance documents |
| Commercial scope | Quantity, requested schedule, drawing approval needs, accessories and any sample or evaluation requirement |
Request a Configuration & Quote →
11 / PRODUCT GUIDE
From Application Review to Handover
Submit the operating conditions
Provide the liquid, flow range, connection and receiving electronics. A sketch of the available installation space helps with the review.
Review the proposed configuration
Check the offered range, materials, thread details, output and power requirements. Resolve differences before ordering.
Agree the supply and documentation
Confirm accessories, calibration data, instructions and any requested evaluation or inspection documents in the quotation.
Verify and record the installation
Check delivered identification against the order, then record the accepted setup and receiving-system scaling after commissioning.
12 / PRODUCT GUIDE
Buyer Questions, Answered
Is this a clamp-on flow meter?
No. The pictured small-bore turbine sensor is installed in the liquid line. It contains a moving rotor and requires a suitable threaded connection and mechanical installation.
What is the minimum flow rate?
It depends on the selected size, liquid and calibrated operating range. Provide the minimum, normal and maximum flow; a small connection size alone is not a minimum-flow specification.
Can I connect the pulse cable directly to a PLC?
Only after the electrical interface is matched. Confirm the signal form, input type, levels, wiring, counter capability and any required supply or signal conditioner.
Does it include a display or RS485?
The pictured cable pickup does not establish those functions. Request a matched display or transmitter configuration if current output, communication or local indication is needed.
Can it measure viscous or contaminated liquids?
Viscosity can change the calibration, while particles and fibres can affect the rotor. Submit the actual liquid conditions for review; do not assume suitability for slurries or every liquid.
What should I request with the quotation?
Ask for the size-specific flow range, pressure and temperature limits, connection drawing, wetted materials, electrical details, calibration information and agreed accessories.
Get the Meter and the Interface Specified Together
Share your liquid, flow range, threaded connection and receiving input. Ask FlowT to confirm a configuration that fits the process and the equipment around it.
You can also use the FlowT enquiry page to submit drawings and project requirements.
Hot Tags: small bore turbine flow meter, pulse liquid turbine flowmeter, LWGY turbine flow meter, threaded liquid flow sensor, turbine flow meter pulse output, oil and gas vortex flow meter, vortex flow meter budget friendly, vortex flow meter reliability, vortex flow meter replacement, manufacturing vortex flow meter, vortex flow meter validations