Ultrasonic Clamp-On Flow Meter for Non-Invasive Flow Measurement

Measure liquid flow from outside the pipe without cutting, drilling or placing a measuring element directly into the process stream. FlowT ultrasonic clamp-on flow meters are designed for existing pipelines, HVAC systems, water treatment, industrial utilities and retrofit projects where installation flexibility and process continuity matter.
FlowT supports fixed, wall-mounted and application-specific ultrasonic flow measurement configurations for project buyers, system integrators, distributors and industrial users. Send us your pipe diameter, wall thickness, material, liquid, temperature and required outputs so our team can help review the suitable configuration before quotation.
FEATURE 01
Non-invasive measurement from outside the pipe
FEATURE 02
No pipe cutting or additional flow obstruction
FEATURE 03
Suitable for existing pipeline and retrofit projects
FEATURE 04
Fixed and project-specific configurations available
FEATURE 05
Industrial output and communication options
FEATURE 06
Application-based model and transducer selection
Built for Practical Industrial Flow Measurement
Lower Installation Complexity
Adding an inline flow meter can require pipe cutting, flanges, welding and shutdown planning. A properly selected ultrasonic clamp-on flow meter provides an alternative when buyers want to reduce mechanical installation work on an existing pipeline.
Support Permanent or Temporary Measurement
Depending on the selected model, clamp-on ultrasonic technology can support permanent monitoring, temporary flow verification, commissioning and troubleshooting.
Wide Application Flexibility
Different transducer configurations can support a broad range of pipe sizes, materials and temperatures. Final suitability should always be confirmed according to the actual pipe and liquid conditions.
Industrial System Integration
FlowT can review the required analog, pulse, relay or digital communication interface according to the selected model so engineers can plan connection to PLC, BMS, SCADA or data-acquisition systems.
No Moving Measuring Parts in the Flow Path
External ultrasonic measurement avoids adding mechanical moving elements inside the process stream, reducing concerns about wear and obstruction associated with some traditional meter technologies.
Application-Based Product Selection
FlowT reviews more than nominal pipe diameter. Pipe wall thickness, material, liner, liquid, temperature, flow conditions and installation location should all be considered before final model selection.
Send Your Application for Technical Review
Find the Right Clamp-On Ultrasonic Flow Meter for Your Application
Different flow measurement projects require different instrument configurations. FlowT can help buyers select a suitable clamp-on ultrasonic flow meter according to measurement duration, pipe size, installation environment, required outputs and monitoring purpose.

Fixed Clamp-On Ultrasonic Flow Meter
Designed for permanent or long-term monitoring of liquid flow in industrial, water and building-service pipelines.
Best for: Plant monitoring, water networks, process water and continuous measurement.

Wall-Mounted Ultrasonic Flow Meter
A fixed transmitter configuration suitable for applications requiring local display, flow totalization and integration with external monitoring or control systems.
Best for: HVAC, water treatment, industrial automation and utility monitoring.

Portable Clamp-On Ultrasonic Flow Meter
Designed for temporary measurement, commissioning, system balancing, troubleshooting and multi-point flow verification.
Best for: Field engineers, maintenance teams, energy audits and commissioning.

Clamp-On BTU / Energy Measurement
Selected ultrasonic configurations can be combined with temperature measurement for thermal-energy monitoring where supported by the confirmed model.
Best for: Chilled water, hot water and building energy management.
Tell Us How You Plan to Use the Meter
Why Choose Clamp-On Ultrasonic Flow Measurement?
Measure Without Pipe Modification
The ultrasonic transducers are installed on the external pipe surface, allowing flow measurement without automatically cutting or opening the process pipeline.
01
Minimize Process Interruption
For existing systems, clamp-on measurement can help reduce the need for shutdown, draining, welding and recommissioning work associated with installing an inline meter.
02
No Additional Pressure Drop
Because the measuring sensors remain outside the pipe, no measuring element is inserted into the flow path.
03
Easier Access for Inspection
External transducers remain accessible from outside the pipe, which can simplify inspection, repositioning and servicing.
04
Suitable for Retrofit Projects
Clamp-on technology is particularly useful when flow measurement needs to be added to an existing water, HVAC or industrial pipeline.
05
Specifications
| Performance | |
|---|---|
| Flow Range | ±0.09ft/s ~ ±40ft/s (±0.03m/s ~ ±12m/s) |
| Accuracy | ±0.5% of reading (for ±1.5ft/s ~ ±40ft/s) |
| Repeatability | 0.15% of measured value |
| Linearity | ±0.5% |
| Pipe Size | 1" to 200" (25mm to 5000mm). Pipe size under 1" is an option. |
| Function | |
| Outputs | Analog output: 4~20mA, max load 750Ω. Pulse output: 0~9999Hz, OCT (min. and max. frequency is adjustable). Relay output: SPST, max 1Hz, 1A@125VAC or 2A@30VDC. |
| Communication | RS232 & RS485 |
| Memory | TF card (Max 4G) |
| Power Supply | 90 to 245 VAC, 48 to 63 Hz, or 10 to 36 VDC |
| Display | 240 × 128 back-lit LCD |
| Temperature | Transmitter: -40°F ~ 140°F (-40°C ~ 60°C) Transducer: -40°F ~ 176°F (-40°C ~ 80°C, standard) |
| Humidity | Up to 99% RH, non-condensing |
| Physical | |
| Transmitter | IP65 |
| Transducer | IP68 Encapsulated design Double-shielded transducer cable Standard / maximum cable length: 30ft / 900ft (9m / 274m) |
Clamp-On Ultrasonic Flow Meter vs. Typical Inline Flow Meter
| Comparison | Clamp-On Ultrasonic Flow Meter | Typical Inline Flow Meter |
|---|---|---|
| Pipe Cutting | Normally not required | Normally required |
| Sensor Contact with Liquid | No | Yes |
| Retrofit Installation | Strong advantage for existing pipelines | Usually requires mechanical pipe modification |
| Process Shutdown | Can often be minimized or avoided during installation | Frequently required for installation |
| Flow Obstruction | No sensor inserted into the flow path | Depends on meter technology |
| Added Pressure Loss | No additional obstruction from clamp-on sensors | Depends on meter design and technology |
| Sensor Access | External sensors remain accessible | May require access to the pipeline or meter body |
| Large Pipe Installation | Can reduce mechanical installation work on large existing pipes | Meter body and piping work may increase with pipe size |
| Maintenance | External transducers are easier to inspect and service | Maintenance requirements depend on meter technology |
| Application Flexibility | Transducer selection can be matched to pipe size, material and temperature | Meter body must be selected for the exact line size and process connection |
| Measurement Dependence | Performance depends on pipe condition, liquid properties and installation quality | Performance depends on meter type, process conditions and installation |
| Typical Best Use | Retrofit projects, existing pipelines, HVAC, water systems and non-invasive monitoring | New installations and applications where direct process measurement is preferred |
FAQ
Q: What is an ultrasonic clamp-on flow meter?
A: An ultrasonic clamp-on flow meter measures liquid flow using ultrasonic transducers mounted on the outside of a pipe. The sensors transmit ultrasonic signals through the pipe wall and liquid, allowing flow measurement without placing a measuring element directly into the process stream.
Q: Does a clamp-on ultrasonic flow meter require pipe cutting?
A: No pipe cutting is normally required for an external clamp-on installation. The sensors are mounted on the pipe surface, which is why the technology is commonly selected for retrofit and existing-pipeline applications.
Q: Can the meter be installed while the system is operating?
A: In many suitable applications, clamp-on sensors can be installed without opening the pipe or draining the process. Final installation procedures should still follow site safety and FlowT installation requirements.
Q: What liquids can be measured?
A: Transit-time clamp-on ultrasonic meters are generally best suited to liquids that provide stable ultrasonic transmission. Clean water, chilled water, hot water and many industrial liquids are common applications. Liquids with significant solids or gas bubbles require additional review.
Q: What pipe sizes can be measured?
A: The supported pipe range depends on the selected FlowT meter and transducer configuration. Send your pipe outside diameter and application conditions so the correct sensor range can be confirmed.
Q: What pipe materials are suitable?
A: Many metallic and plastic pipe materials can be evaluated for ultrasonic clamp-on measurement. Pipe wall thickness, lining, corrosion and acoustic properties must also be considered.
Q: How accurate is a clamp-on ultrasonic flow meter?
A: Accuracy depends not only on the instrument but also on pipe dimensions, liquid condition, sensor installation, straight-run availability and flow profile. The final accuracy specification should be confirmed for the selected FlowT model and application.
Q: Can the meter measure bidirectional flow?
A: Bidirectional measurement is supported by many ultrasonic flow meter configurations, but the exact capability should be confirmed for the selected model.
Q: Can the flow meter connect to a PLC or BMS?
A: Industrial communication options can be reviewed according to the selected FlowT model. Common project requirements include analog output, pulse, relay and RS485/Modbus communication.
Q: Can FlowT help select the correct model?
A: Yes. Send FlowT the pipe diameter, material, wall thickness, liquid, temperature, expected flow range and measurement purpose. The team can use this information to review the appropriate configuration.
Q: Do you support OEM or distributor orders?
A: FlowT supports project and repeat-order discussions with distributors, system integrators and OEM buyers. Branding, packaging and configuration requirements should be confirmed during quotation.
Q: Can I request a datasheet or calibration information?
A: Yes. Product datasheets, installation documentation and applicable calibration information can be requested according to the selected FlowT product.

Not Sure Which Clamp-On Ultrasonic Flow Meter Fits Your Application?
Send FlowT your pipe diameter, wall thickness, pipe material, liquid, operating temperature, expected flow range and required communication interface.Our team can review the application conditions and help identify the fixed, wall-mounted, portable or application-specific ultrasonic flow meter configuration that should be evaluated.
For distributors, system integrators and project buyers, please also provide your quantity, destination country, documentation requirements and project timeline.
Hot Tags: ultrasonic clamp on flow meter, China ultrasonic clamp on flow meter manufacturers, suppliers, factory, ultrasonic flow meter for aquaculture, ultrasonic flow meter for flow monitoring, ultrasonic flow meter for flow measurement in ducts, ultrasonic flow meter for marine, ultrasonic flow meter availability, ultrasonic flow meter benefits